Ninthore Overseas is one of the Leading Manufacturer And Exporter Of High Quality Cupro Nickel 90 Tube to Male Fittings, where we are made these for utilizing superb raw materials. Typically, Cu-Ni 90 / 10 Tube Fittings is used as sea water condenser systems and desalination plants owing to good resistance against sea water corrosion and also for pipe work in chemical plants. Cupro Nickel 90 / 10 Compression Fittings are a copper-nickel alloy with an alpha – phase structure, which exhibits superior corrosion resistance in seawater. Copper Nickel 90 / 10 Ferrule Tube Fittings are used in the Heat exchangers, Desalination for its very good corrosive resistance.

Cupro Nickel 90 Tube to Male Fittings Manufacturer In India | Cupro Nickel 90 Tube to Male Fittings Manufacturer In Mumbai | Cupro Nickel 90 Tube to Male Fittings Exporter In India | Cupro Nickel 90 Tube to Male Fittings Exporter In Mumbai | Cupro Nickel 90 Tube to Male Fittings Supplier In India | Cupro Nickel 90 Tube to Male Fittings Supplier In Mumbai | Cupro Nickel 90 Tube to Male Fittings Stockist In India | Cupro Nickel 90 Tube to Male Fittings Stockist In Mumbai 
Cupro Nickel 90 Tube to Male Fittings

Cupro Nickel 90 Tube to Male Fittings

Furthermore, Cu-Ni 90 / 10 Double Ferrule Tube Fittings is resistant to bio-fouling pro viding various economic benefits, and is relatively insensitive to stress corrosion. Cupro Nickel 90 / 10 Male Connector Fittings contain 90 % copper and differ in strength and maximum sea water velocity levels they can handle but it is also the more economic and extensively used.

Copper Nickel 90 / 10 Compression Tube Fittings is often used in Condensers, Condenser Plates, Evaporator Tubes , Ferrules , Heat Exchanger Tubes, Corrosion Resistance, Petrochemicals, Salt Water, Erosion and Impingement, Moderate Strength, Retains Strength at High Temperatures. Cu-Ni 90 / 10 Male Connector Tube Fittings has nominal temperature coefficient of electric resistance, which is suitable for Marine condenser tube installations in place of Aluminum Brass, especially where higher water velocities are encountered.

Cupro Nickel 90/10 Tube to Male Fittings Specifications
Specifications : ASTM B366 ASME SB366
Tube Size : 6mm to 38mm to 1/4″ to 1 1/2″
Thread
: NPT, BSP, BSPT, UNF, ISO, SAE etc.
Brass : ASTM B16 ASTM B 453
Pressure Rating : 6000PSI for Nickel, 300/1000/3000PSI for Brass
Cu-Ni 90/10 Tube To Male Fittings Chemical Composition
Grade Cu Mn Pb Ni Fe Zn
Cupro Nickel 90/10 88.6 min 1.0 max 0.05 max 9-11 max 1.8 max 1 max
Cupro Nickel 90/10 Tube To Male Fittings Mechanical Properties
Density Melting Point Tensile Strength Yield Strength (0.2%Offset) Elongation
0.323 lb/in3 at 68 F 2260 F 50000 psi 20000 psi 30 %
Equivalent Grades for 90/10 Cupro Nickel Ferrule Fitting Tube To Male Fittings
STANDARD WERKSTOFF NR. UNS
Cupro Nickel 90/10 2.0872 C70600
Cu-Ni 90/10 Tube To Male Fittings Application Industries
  • Off-Shore Oil Drilling Companies
  • Power Generation
  • Petrochemicals
  • Gas Processing
  • Specialty Chemicals
  • Pharmaceuticals
  • Pharmaceutical Equipment
  • Chemical Equipment
  • Sea Water Equipment
  • Heat Exchangers
  • Condensers
  • Pulp and Paper Industry
Cupro Nickel 90/10 Tube To Male Fittings Test Certificates

We at Ninthore Overseas provide Manufacturer TC (Test Certificate) in accordance to EN 10204/3.1B, Raw Materials Certificate, 100% Radiography Test Report, Third Party Inspection Report. We also provide Standard certificates like EN 10204 3.1 and additional requirement like. NACE MR 01075. FERRIT CONTENT as per norms if requested by clients.

• EN 10204/3.1B,
• Raw Materials Certificate
• 100% Radiography Test Report
• Third Party Inspection Report, etc

Material Testing
We at Ninthore Overseas ensure that all our materials go through strict quality tests before dispatching them to our clients.

• Mechanical Testing Such as Tensile of Area
• Hardness Test
• Chemical Analysis – Spectro Analysis
• Positive Material Identification – PMI Testing
• Flattening Test
• Micro and Macro Test
• Pitting Resistance Test
• Flaring Test
• Intergranular Corrosion (IGC) Test

Documentation

• Commercial Invoice which includes HS Code
• Packing List including net weight and gross weight, number of boxes, Marks and Numbers
• Certificate of Origin legalized/attested by Chamber of Commerce or Embassy
• Fumigation Certificates
• Raw Material Test Reports
• Material Traceability Records
• Quality Assurance Plan (QAP)
• Heat Treatment Charts
• Test Certificates certifying NACE MR0103, NACE MR0175
• Material Test Certificates (MTC) as per EN 10204 3.1 and EN 10204 3.2
• Guarantee Letter
• NABL approved Laboratory Test Reports
• Welding Procedure Specification/Procedure Qualification Record, WPS/PQR
• Form A for the purposes of the Generalized System of Preferences (GSP)

 

Cupro Nickel 90 Tube to Male Fittings

Ninthore Overseas is one of the Leading Manufacturer And Exporter Of High Quality Cupro Nickel 90 Tube to Male Fittings, where we are made these for utilizing superb raw materials. Typically, Cu-Ni 90 / 10 Tube Fittings is used as sea water condenser systems and desalination plants owing to good resistance against sea water corrosion and also for pipe work in chemical plants

Product Brand: Ninthore Overseas

Product In-Stock: InStock

Editor's Rating:
5